Request a service

Troubleshooting Guide for Comfee Split Air Conditioners

If your Comfee split air conditioner isn’t working as expected, follow this guide to diagnose and resolve common issues.

  1. AC Not Cooling Properly

βœ… Possible Causes & Solutions:

Dirty air filter: Clean or replace the filter.

Incorrect temperature setting: Ensure the temperature is set lower than room temperature.

Blocked air vents: Remove any obstructions to allow proper airflow.

Low refrigerant level: Contact a technician for a gas refill.

  1. AC Won’t Turn On

βœ… Possible Causes & Solutions:

Power supply issue: Check if the unit is plugged in and the circuit breaker is on.

Remote control battery low: Replace the batteries.

Timer function activated: Ensure no timer settings are preventing operation.

  1. Unusual Noises

βœ… Possible Causes & Solutions:

Loose parts: Check for any loose screws or components.

Dirty fan blades: Clean the indoor and outdoor unit fans.

Debris in outdoor unit: Remove leaves or objects near the compressor.

  1. Water Leaking from Indoor Unit

βœ… Possible Causes & Solutions:

Clogged drain pipe: Clean the drainage system.

Improper installation: Ensure the unit is level.

Frozen evaporator coil: Turn off the AC and allow it to defrost before restarting.

  1. Remote Control Not Working

βœ… Possible Causes & Solutions:

Weak or dead batteries: Replace them with new ones.

Obstruction between remote and AC: Ensure nothing is blocking the signal.

Remote sensor issue: Wipe the sensor on the remote and indoor unit.

Comfee Split Air Conditioner Error Codes & Troubleshooting

If your Comfee split air conditioner displays an error code, use this guide to understand the issue and possible solutions.

Common Error Codes & Their Fixes

πŸ”΄ E0 – EEPROM Communication Error

βœ… Solution: Restart the AC. If the error persists, call a technician.

πŸ”΄ E1 – High Pressure Protection

βœ… Solution:

  • Clean or replace the air filter.
  • Check for obstructions in the outdoor unit.
  • Ensure proper ventilation around the AC.

πŸ”΄ E2 – Indoor Coil Anti-Freezing Protection

βœ… Solution:

  • Turn off the unit and allow it to defrost.
  • Clean the air filter.
  • Ensure no airflow blockages.

πŸ”΄ E3 – Low Pressure Protection

βœ… Solution: Contact a technician to check refrigerant levels and system pressure.

πŸ”΄ E4 – Discharge Temperature Protection

βœ… Solution:

  • Ensure the outdoor unit is not overheating.
  • Check refrigerant levels (call a technician).

πŸ”΄ E5 – Overcurrent Protection

βœ… Solution:

  • Ensure the power supply is stable.
  • If the error persists, call a technician.

πŸ”΄ E6 – Communication Error Between Indoor & Outdoor Unit

βœ… Solution:

  • Turn off the AC and restart after 5 minutes.
  • If the error remains, call a professional.

πŸ”΄ E7 – Mode Conflict Error

βœ… Solution: Ensure no other AC unit is set to a conflicting mode (e.g., one cooling, one heating).

πŸ”΄ P1 – Voltage Protection

βœ… Solution: Check if the voltage is within the required range. Use a stabilizer if necessary.

πŸ”΄ P2 – Compressor Overload

βœ… Solution: Turn off the AC, allow it to cool, and restart. If the error remains, call a technician.

πŸ”΄ P4 – Inverter Module Protection

βœ… Solution: Restart the unit. If the error persists, consult a professional.

Keep your Comfee split air conditioner running efficiently with these simple maintenance tips!

Clean or Replace Air Filters (Every 2-4 Weeks)

βœ… Remove dust and debris to maintain airflow and cooling efficiency.
βœ… Wash reusable filters with mild soap and water, then dry completely before reinstalling.


2️⃣ Keep the Indoor & Outdoor Units Clean

βœ… Wipe the indoor unit with a soft cloth to remove dust.
βœ… Check the outdoor unit for dirt, leaves, and debris that may block airflow.


3️⃣ Inspect & Clean the Drain Pipe

βœ… Prevent water leakage by checking for blockages in the drainage system.
βœ… Flush with warm water or mild detergent if needed.


4️⃣ Check Refrigerant Levels

βœ… Low refrigerant can reduce cooling efficiency.
βœ… If cooling performance drops, call a technician for inspection.


5️⃣ Ensure Proper Airflow Around the Outdoor Unit

βœ… Keep at least 2-3 feet of clearance around the unit.
βœ… Remove any objects blocking air circulation.


6️⃣ Schedule Professional Servicing (Every 6-12 Months)

βœ… Have a technician check internal components, gas levels, and electrical connections.
βœ… Helps prevent costly repairs and ensures peak performance.